3 Way light Switch Controlling Multiple Lights Diagram

3 Way light Switch Controlling Multiple Lights Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com In this scenario the 3 way switches controls two light fixtures. Many applications where 3 way switching is required. For example, in a house you might […]
Read more

3 Way Switches Power Into Light Diagram

3 Way Switches Power Into Light Diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com In this scenario the power source is directly into the light fixture box. A three-way switch is designed to control power in any home. There are […]
Read more

Accessibility of junction boxes

Accessibility of junction boxes 1) Pull-in, junction, and outlet boxes, cabinets and gutters, and joints in conductors and cables shall be accessible. 2) A vertical space of 900 mm or more shall be required to provide ready access Source: Rule 12-3014, CSA C22.1:21, Canadian Electrical Code, Part 1 (25th Edition), Safety Standard for Electrical Installations. […]
Read more

Areas of Combination Bedrooms

(1)  Bedroom spaces in combination with other spaces in dwelling units shall have an area not less than 4.2 m². Article 9.5.7.3 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Areas of Living Rooms and Spaces

Areas of Living Rooms and Spaces (1)  Living areas within dwelling units, either as separate rooms or in combination with other spaces, shall have an area not less than 13.5 m². (2)  Where the area of a living space is combined with a kitchen and dining area, the living area alone in a dwelling unit that contains […]
Read more

Areas of Other Sleeping Rooms

Areas of Other Sleeping Rooms (1)  Sleeping rooms other than in dwelling units shall have an area not less than 7 m² per person for single occupancy and 4.6 m² per person for multiple occupancy. Article 9.5.7.4 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Basic 3 Way Switch Wiring

Basic 3 Way Switch Wiring Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note: A multi-way switch is a device that allows you to control the power supply to more than one electrical load. It works by supplying power from a single […]
Read more