Slab Construction Over Cold Storage Room in Basements
Slab Construction Over Cold Storage Room in Basements Refer to Article 9.39.1.1 if it applies (1) Concrete shall be cast against form work in accordance with CSA A23.1, “Concrete Materials and Methods of Concrete Construction”. (2) The slab shall be not less than 125 mm thick. (3) The slab shall be reinforced with 10M bars spaced not more than 200 […]
Read more →