Furring
(1) Except as permitted in Sentence 9.27.5.1. (4), furring for the attachment of cladding shall be not less than 19 mm by 38 mm lumber when applied over sheathing.
(2) When applied without sheathing, furring referred to in Sentence (1) shall be not less than,
(a) 19 mm by 64 mm lumber on supports spaced not more than 406 mm o.c., or
(b) 19 mm by 89 mm on supports spaced not more than 610 mm o.c.
(3) Furring referred to in Sentence (1) shall be,
(a) securely fastened to the framing, and
(b) spaced not more than 610 mm o.c.
Article 9.27.5.3. Ontario Regulation 332/12 Building Code, Information published by oncodes.ca for educational purposes only