Copyright information: © Queen’s Printer for Ontario Overview Ontario.ca has information and materials created by government ministries, agencies, third parties, external stakeholders and other partners. This page explains how to use and re-use these materials. Unless otherwise indicated, the materials on this website are protected by Crown copyright, which is held by the Queen’s Printer […]
Read more

Copyright Information CSA Group

Oncodes.ca obtains permission to reproduce copyrighted material from standard CSA C22.1:21, Canadian Electrical Code, Part 1 (25th Edition), Safety Standard for Electrical Installations (“Standard”), owned by the Canadian Standards Association, (operating as “CSA Group”). With the permission of Canadian Standards Association, (operating as “CSA Group”), 178 Rexdale Blvd., Toronto, ON, M9W 1R3, material is reproduced […]
Read more

Curved Flights in Exits

Curved Flights in Exits (1)  Flights used as an exit shall consist solely of,     (a)   straight flights, or     (b)   curved flights complying with Sentence (2).     (2)  A curved flight used as an exit shall have,     (a)   a handrail on each side,     (b)   treads with a minimum run of 240 mm,     (c)   […]
Read more

Deviation or postponement

Deviation or postponement In any case where deviation or postponement of these Rules and regulations is necessary, specialpermission shall be obtained before proceeding with the work, but this special permission shall applyonly to the particular installation for which it is given. Source: Rule 2-030, CSA C22.1:21, Canadian Electrical Code, Part 1 (25th Edition), Safety Standard […]
Read more

Door Release Hardware

Door Release Hardware (1)  Except for dwelling units, except for devices on doors serving a contained use area or an impeded egress zone designed to be released in conformance with Article 3.3.1.12., and except as permitted by Sentence (4), locking, latching and other fastening devices on every exit door shall permit the door to be readily […]
Read more

Doorways and Doors

Doorways and Doors (1)  Every doorway that is located in a barrier-free path of travel shall have a clear width of not less than 860 mm when the door is in the open position.     (2)  Except as provided in Sentence 3.3.4.11.(11) and except where no bathroom within the suite is at the level of the suite […]
Read more

Drainage Tile and Pipe Minimum Size

Drainage Tile and Pipe Minimum Size (1)  Drain tile or pipe used for foundation drainage shall be not less than 100 mm in diam. Article 9.14.3.2. Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.