Height of Guards

Height of Guards (1)  Except as provided in Sentences (2), (3), (4) and (6), all guards shall be not less than 1 070 mm high. (2)  All guards within dwelling units, other than guards serving spiral stairs, shall be not less than 900 mm high. (3)  Exterior guards serving a house or an individual dwelling unit shall be […]
Read more

Height of Handrails

Height of Handrails (1)  The height of handrails on stairs and ramps shall be measured vertically from the top of the handrail to,     (a)   a straight line drawn tangent to the tread nosings of the stair served by the handrail, or     (b)   the surface of the ramp, floor or landing served by the handrail. […]
Read more

Height over Landings

(1)  The clear Height over landings shall be not less than,     (a)   1 950 mm for landings serving a house or an individual dwelling unit, and     (b)   2 050 mm for landings not serving a house or an individual dwelling unit. Article 9.8.6.4 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for […]
Read more

Height over Stairs

(1)  The clear height over stairs shall be measured vertically, over the clear width of the stair, from a straight line tangent to the tread and landing nosings to the lowest point above. (2)  Except as provided in Sentence (3) and Article 9.8.4.5A., the clear height over stairs shall not be less than 2 050 mm                […]
Read more

Hot Water Supply

Hot Water Supply (1)  In a dwelling unit with a water distribution system, a hot water supply shall be provided. (2)  A water distribution system supplying hot water to plumbing fixtures shall conform to the requirements in Subsection Article 9.31.4.3 Ontario Regulation 332/12 Building Code,   O. Reg. 332/12: BUILDING CODE (ontario.ca) © Queen’s Printer for Ontario, […]
Read more

Hot Water Temperature

Hot Water Temperature (1)  Where a hot water supply is required by Article 9.31.4.3., equipment shall be installed to provide to every dwelling unit an adequate supply of service hot water with a temperature range from 45°C to 60°C. (2)  An electric storage-type service water heater shall have a minimum set storage temperature of 60°C. Article 9.31.6.1 […]
Read more

Hunter ceiling fan installation guide

Hunter ceiling fan installation guide ATTENTION. Please have the work done by a qualified professional. Validate that the bumpers are well in place Use the #8 wood screw to solidify the assembly into a wood backing Move the wires into the box and slide the base in. It should fit nice and level If the […]
Read more